The WHF-HM High Mount heater is designed for applications to be mounted 6’ above the floor. It is commonly used where wall space is limited. The high wall mounting allows you to use absolutely any wall in a room without affecting the furniture or decor placement. The WHF-HM provides extreme value by combining an open coil Ni-chrome wire element and squirrel cage blower.
Product Features
Warmth From Above. Out Of The Way Of Furniture
Mounts 6 Feet Above The Floor
WHF-HM is commonly used where wall space is limited. The high wall mounting allows you to use absolutely any wall in a room without affecting the furniture or decor placement.
Now That’s Smart!
Available Models
Ordering Information
BASE MODEL | VOLTS | WATTS | AMPS | SHIP WEIGHT lbs |
---|---|---|---|---|
WHF1210-HM | 120 | 500 - 1000 | 4.2 - 8.3 | 8 |
WHF1212-HM | 120 | 600 - 1200 | 5.0 - 10.0 | 8 |
WHF1215-HM | 120 | 750 - 1500 | 6.3 - 12.5 | 8 |
WHF2010-HM | 208 | 500 - 1000 | 2.4 - 4.8 | 8 |
WHF2015-HM | 208 | 750 - 1500 | 3.6 - 7.2 | 8 |
WHF2020-HM | 208 | 1000 - 2000 | 4.8 - 9.6 | 8 |
WHF2410-HM | 240/208* | 500 - 1000 | 2.1 - 4.2 | 8 |
WHF2412-HM | 240/208* | 600 - 1200 | 2.5 - 5.0 | 8 |
WHF2415-HM | 240/208* | 750 - 1500 | 3.1 - 6.2 | 8 |
WHF2420-HM | 240/208* | 1000 - 2000 | 4.2 - 8.4 | 8 |
Ordering Information - Factory Installed Options
ADD SUFFIX | DESCRIPTION | SHIP WEIGHT lbs |
---|---|---|
-W | White Color | 8 |
-H | Heatbox Interior Only (no can or grill) | 3.5 |
-I | Heatbox Interior and Grill Only (no wall can) | 5.5 |
Order A'la Carte Step 1 - Ordering Information
ADD SUFFIX | DESCRIPTION | SHIP WEIGHT lbs |
---|---|---|
-H | Heatbox Interior Only (no can or grill) | 3.5 |
-I | Heatbox Interior and Grill Only (no wall can) | 5.5 |
Order A'la Carte Step 2 - Ordering Information
MODEL | UPC | DESCRIPTION | SHIP WEIGHT lbs | Purchase |
---|---|---|---|---|
UIC | 12640 | Recess Wall Can | 3.5 | Buy Now |
UICF | 12540 | Recess Can with Flange (remodel) | 4 | |
WHSC-W | 19204 | Surface Can - White - 13.5" H x 10.125" W x 4" D | 4 | |
WHSC-A | 19205 | Surface Can - Almond - 13.5" H x 10.125" W x 4" D | 4 |
Order A'la Carte Step 3 - Ordering Information
MODEL | UPC | DESCRIPTION | SHIP WEIGHT lbs |
---|---|---|---|
WHFG-HM-A | 13509 | WHF ACCY GRILL FOR HIGH MOUNT HEATER ALMOND | 2 |
WHFG-HM-W | 12020 | WHF ACCY GRILL FOR HIGH MOUNT HEATER WHITE | 2 |
Ordering Information - Accessories
MODEL | UPC | DESCRIPTION | SHIP WEIGHT lbs | Purchase |
---|---|---|---|---|
TKIT-1BW | 20654 | Built-in Single Pole Single Throw Thermostat Kit, Bright White | 0.5 | Buy Now |
TKIT-2BW | 20655 | Built-in Double Pole Single Throw Thermostat Kit, Bright White | 0.5 | Buy Now |
TKIT-1A | 11058 | Built-in Single Pole Single Throw Thermostat Kit, Almond | 0.5 | Buy Now |
TKIT-2A | 11059 | Built-in Double Pole Single Throw Thermostat Kit, Almond | 0.5 | Buy Now |
TKIT-1-TP | 11056 | Built-in Tamper Proof Single Pole Single Throw Thermostat Kit | 0.4 | Buy Now |
TKIT-2-TP | 11057 | Built-in Tamper Proof Double Pole Single Throw Thermostat Kit | 0.4 | Buy Now |
DS15 | 13824 | Disconnect Switch, Field Installed Kit, 10Amp 240V/15A 120V | 0.5 | Buy Now |
Engineering Specs
Contractor shall supply and install WHF-HM Series in-wall mounted forced-air electric heaters manufactured by King Electrical Mfg. Company. Heaters shall be of the wattage and voltage as indicated on the plans.
Ratings: Heaters shall be available in wattages of 500 to 2,000 at 120, 208, or 240 Volts
Blower and Motor: A whisper quiet tangential blower, delivering 75 CFM, shall be driven by a shaded pole, permanently lubricated, C-frame type motor with impedance protection and sealed bearings. Motors shall be the same voltage as the heater. The motor and all wiring shall be totally isolated from the heating chamber for protection from heated air.
Thermal Overload: Heaters shall be equipped with King’s patented thermal overload Smart Limit Protection®, which disconnects elements and motor in the event normal operating temperatures are exceeded. If thermal overload trips due to abnormal operating temperatures, thermal overload shall remain open until manually reset by turning the heater off for 15 minutes. Automatic reset of thermal overloads, which allow the element to continue to cycle under abnormal conditions, will not be accepted.
Elements: Element assemblies shall be constructed of coiled nickel chromium alloy, corrosion resistant wire strung through a minimum of four rows of mica insulator. Element assemblies shall have factory provided connection to allow field modification to 50% wattage at time of installation.
Wall Can: The wall can shall be 20 gauge electrogalvanized steel and shall contain knockouts. The wall can shall be provided with a depth gauge, extending the full length of the wall can. The wall can shall be supplied with a factory installed groundwire. Minimum clearance 72” to floors, 6” to sidewalls, and 4” to the ceiling. Zero clearance to down flow.
Grill: The grill shall be a louvered, one-piece design with rounded edges on all four sides, with rounded corners to prevent snags from contact with other materials. The grill shall be epoxy powder- coated in the color specified by the manufacturer
Approvals: cULus (E41422)