Specify King Electric products with confidence.
Find Out What Specific Advantages King Can Bring to Your Next Project
Reliable electric heating solutions designed for residential, commercial, industrial and institutional applications.
Find the Right Solution for Your Application
Lower Your Energy Bills with Better Controls
Two Heat Levels for More Comfort & Efficiency
Adjusts Temperatures to Reduce Energy Use
Smart heating solutions for residential, commercial and industrial spaces.
Primary Heating Solutions
Specialty & Application Specific
Protection & Environmental Control
Specialty & Application Specific
Industrial & Environmental Control
Hazardous Locations
Protection & Environmental Control
Smart & Application Specific
Built-In & Integrated Controls
Components & Accessories
Snow Melt/Roof & Gutter Controls & Accessories
Pipe Freeze Protection Controls & Accessories
Floor Mounted
Wall Mounted
Parts
King delivers industry leading smart heating solutions with proven performance, expert support and a legacy of quality.
Access Sizing Calculators & Technical Guidance to Design with Confidence.
How To Size Calculators
Electric Heaters
Garage Heaters
Cove Heaters
Industrial Portables
Warehouse/Large Space
Fans
Electrical & System Design
How To Size Heating Circuit
Handy Formulas for Electric Heat
Electrical & System Design
Technical Articles
Application Guides & Whitepapers
Find Spec Sheets, User Manual & Other Technical Details.
Technical Documentation
Spec Sheets
Installation Manuals
Product Documentation
Catalog & Submittals
Product Catalogs
Submittal Packages
BIM & CAD Files
Revit Files
Quick Access to Quotes, Order Status & Technical Support.
Access Sizing Calculators & Technical Guidance to Design with Confidence.
How To Size Calculators
Electric Heaters
Garage Heaters
Cove Heaters
Industrial Portables
Warehouse/Large Space
Fans
Electrical & System Design
Sizing the Heating Circuit
Handy Formulas for Electric Heat
We believe 65+ Years of Experience Matters.
We Build Better Heater by Listening to the People Who Use Them, So We Are Taking it on the Road.



Explosion Proof Heater
kW Range: 2.5 to 35 kW
Voltage: 208 / 240 / 415 / 440 / 480 / 600V
Phase: 1Ø / 3Ø
Mounting: Wall or Ceiling Mount
Enclosure: NEMA Type 7 and 9
Certification: cULus Hazardous Location Certified
Warranty: Refer to King Warranty Terms
Explosion proof industrial heater certified for hazardous locations and harsh dry indoor industrial environments.
The FX6 explosion proof heater is designed for dry indoor hazardous locations and harsh industrial environments where explosive gases or dust may be present. Built with a heavy duty epoxy coated 12 gauge steel cabinet, explosion proof motor, aluminum fan, adjustable louvers, NEMA Type 7 and 9 enclosure, and two levels of over temperature protection, the FX6 provides reliable directional fan forced heat. It is suited for oil refineries, petrochemical plants, pulp and paper mills, grain elevators, hazardous waste facilities, wastewater treatment plants, and similar demanding locations. The FX6 is suitable for extreme low ambient operation down to -58°F (-50°C).
| MODEL | VOLTS | PHASE | NOMINAL WATTAGE (kW) | AMPS | OPTIONAL BUILT-IN DISCONNECT SWITCH | AIR TEMP. RISE | BTU/HR |
|---|---|---|---|---|---|---|---|
| FX6-208160-030 | 208 | 1 | 3 | 18.5 | DS | 11.2°F (6.2°C) | 10250 |
| FX6-208360-030 | 208 | 3 | 3 | 10.6 | DS | 11.2°F (6.2°C) | 10250 |
| FX6-240160-030 | 240 | 1 | 3 | 16.6 | DS | 11.2°F (6.2°C) | 10250 |
| FX6-240360-030 | 240 | 3 | 3 | 9.6 | DS | 11.2°F (6.2°C) | 10250 |
| FX6-480160-030** | 480 | 1 | 3 | 7.1 | DS | 11.2°F (6.2°C) | 10250 |
| FX6-480360-030 | 480 | 3 | 3 | 4.8 | DS | 11.2°F (6.2°C) | 10250 |
| FX6-600360-030 | 600 | 3 | 3 | 3.6 | DS | 11.2°F (6.2°C) | 10250 |
| FX6-208160-050 | 208 | 1 | 5 | 28.1 | DS | 18.6°F (10.3°C) | 17050 |
| FX6-208360-050 | 208 | 3 | 5 | 16.2 | DS | 18.6°F (10.3°C) | 17050 |
| FX6-240160-050 | 240 | 1 | 5 | 24.9 | DS | 18.6°F (10.3°C) | 17050 |
| FX6-240360-050 | 240 | 3 | 5 | 14.4 | DS | 18.6°F (10.3°C) | 17050 |
| FX6-480160-050** | 480 | 1 | 5 | 11.2 | DS | 18.6°F (10.3°C) | 17050 |
| FX6-480360-050 | 480 | 3 | 5 | 7.2 | DS | 18.6°F (10.3°C) | 17050 |
| FX6-600360-050 | 600 | 3 | 5 | 5.5 | DS | 18.6°F (10.3°C) | 17050 |
| FX6-208160-075 | 208 | 1 | 7.5 | 40.2 | DS | 27.9°F (15.5°C) | 25600 |
| FX6-208360-075 | 208 | 3 | 7.5 | 23.1 | DS | 27.9°F (15.5°C) | 25600 |
| FX6-240160-075 | 240 | 1 | 7.5 | 35.4 | DS | 27.9°F (15.5°C) | 25600 |
| FX6-240360-075 | 240 | 3 | 7.5 | 20.5 | DS | 27.9°F (15.5°C) | 25600 |
| FX6-480160-075** | 480 | 1 | 7.5 | 16.4 | DS | 27.9°F (15.5°C) | 25600 |
| FX6-480360-075 | 480 | 3 | 7.5 | 10.2 | DS | 27.9°F (15.5°C) | 25600 |
| FX6-600360-075 | 600 | 3 | 7.5 | 7.9 | DS | 27.9°F (15.5°C) | 25600 |
| FX6-208160-100** | 208 | 1 | 10 | 52.2 | NOT AVAILABLE | 37.2°F (20.6°C) | 34100 |
| FX6-208360-100 | 208 | 3 | 10 | 30.1 | DS | 37.2°F (20.6°C) | 34100 |
| FX6-240160-100 | 240 | 1 | 10 | 45.8 | DS | 37.2°F (20.6°C) | 34100 |
| FX6-240360-100 | 240 | 3 | 10 | 26.5 | DS | 37.2°F (20.6°C) | 34100 |
| FX6-480160-100** | 480 | 1 | 10 | 21.6 | DS | 37.2°F (20.6°C) | 34100 |
| FX6-480360-100 | 480 | 3 | 10 | 13.2 | DS | 37.2°F (20.6°C) | 34100 |
| FX6-600360-100 | 600 | 3 | 10 | 10.3 | DS | 37.2°F (20.6°C) | 34100 |
| FX6-208360-150 | 600 | 3 | 15 | 44 | NOT AVAILABLE | 37.2°F (20.6°C) | 34100 |
| FX6-240160-150* | 240 | 1 | 15 | 66.6 | DS | 27.1°F (15.1°C) | 51200 |
| FX6-240360-150 | 240 | 3 | 15 | 38.5 | DS | 27.1°F (15.1°C) | 51200 |
| FX6-480160-150** | 480 | 1 | 15 | 32.1 | DS | 27.1°F (15.1°C) | 51200 |
| FX6-480360-150 | 480 | 3 | 15 | 19.3 | DS | 27.1°F (15.1°C) | 51200 |
| FX6-600360-150 | 600 | 3 | 15 | 15.2 | DS | 27.1°F (15.1°C) | 51200 |
| FX6-480160-200** | 480 | 1 | 20 | 42.5 | DS | 36.1°F (20.1°C) | 68240 |
| FX6-480360-200 | 480 | 3 | 20 | 25.3 | DS | 36.1°F (20.1°C) | 68240 |
| FX6-600360-200 | 600 | 3 | 20 | 20 | DS | 36.1°F (20.1°C) | 68240 |
| FX6-480360-250 | 480 | 3 | 25 | 31.3 | DS | 22.0°F (12.2°C) | 85300 |
| FX6-600360-250 | 600 | 3 | 25 | 24.8 | DS | 36.1°F (20.1°C) | 85300 |
| FX6-480360-300 | 480 | 3 | 30 | 37.3 | DS | 26.4°F (14.6°C) | 102350 |
| FX6-600360-300 | 600 | 3 | 30 | 29.6 | DS | 26.4°F (14.6°C) | 102350 |
| FX6-480360-350 | 480 | 3 | 35 | 43.3 | DS | 30.7°F (17.1°C) | 119450 |
| FX6-600360-350 | 600 | 3 | 35 | 34.4 | DS | 30.7°F (17.1°C) | 119450 |
| MODEL | VOLTS | PHASE | NOMINAL WATTAGE (kW) | AMPS | OPTIONAL BUILT-IN DISCONNECT SWITCH | AIR TEMP. RISE | BTU/HR |
|---|---|---|---|---|---|---|---|
| FX6-220150-025 | 220 | 1 | 2.5 | 16.1 | DS | 11.2°F (6.3°C) | 8550 |
| FX6-220150-042 | 220 | 1 | 4.2 | 23.8 | DS | 19.0°F (10.5°C) | 14350 |
| FX6-220150-063 | 220 | 1 | 6.3 | 33.3 | DS | 28.5°F (15.7°C) | 21500 |
| FX6-220150-084 | 220 | 1 | 8.4 | 42.9 | DS | 37.8°F (21.1°C) | 28700 |
| FX6-220150-126* | 220 | 1 | 12.6 | 62 | NOT AVAILABLE | 27.5°F (15.2°C) | 43000 |
| FX6-230150-028 | 230 | 1 | 2.8 | 16.3 | DS | 12.5°F (7.0°C) | 9550 |
| FX6-230150-046 | 230 | 1 | 4.6 | 24.1 | DS | 20.7°F (11.5°C) | 16000 |
| FX6-230150-069 | 230 | 1 | 6.9 | 34.1 | DS | 31.1°F (17.2°C) | 23550 |
| FX6-230150-138* | 230 | 1 | 13.8 | 64.1 | NOT AVAILABLE | 30.1°F (16.6°C) | 47100 |
| FX6-380350-025 | 380 | 3 | 2.5 | 4.9 | DS | 11.2°F (6.3°C) | 8550 |
| FX6-380350-042 | 380 | 3 | 4.2 | 7.5 | DS | 19.0°F (10.5°C) | 14350 |
| FX6-380350-063 | 380 | 3 | 6.3 | 10.7 | DS | 28.5°F (15.7°C) | 21500 |
| FX6-380350-084 | 380 | 3 | 8.4 | 13.9 | DS | 37.8°F (21.1°C) | 28700 |
| FX6-380350-125 | 380 | 3 | 12.5 | 20.1 | DS | 27.5°F (15.2°C) | 42700 |
| FX6-380350-209 | 380 | 3 | 20.9 | 32.9 | DS | 22.0°F (12.1°C) | 71350 |
| FX6-400350-028 | 400 | 3 | 2.8 | 5.1 | DS | 12.5°F (7.0°C) | 9550 |
| FX6-400350-046 | 400 | 3 | 4.6 | 7.7 | DS | 20.7°F (11.5°C) | 15700 |
| FX6-400350-069 | 400 | 3 | 6.9 | 11.1 | DS | 31.1°F (17.2°C) | 23550 |
| FX6-400350-093 | 400 | 3 | 9.3 | 14.5 | DS | 42.0°F (23.2°C) | 31750 |
| FX6-400350-139 | 400 | 3 | 13.9 | 21.1 | DS | 30.2°F (16.7°C) | 74450 |
| FX6-400350-185 | 400 | 3 | 18.5 | 27.8 | DS | 40.2°F (22.3°C) | 63150 |
| FX6-400350-231 | 400 | 3 | 23.1 | 34.5 | DS | 24.2°F (13.5°C) | 78850 |
| FX6-415350-037 | 415 | 3 | 3.7 | 6.4 | DS | 16.6°F (9.2°C) | 12650 |
| FX6-415350-075 | 415 | 3 | 7.5 | 11.6 | DS | 33.8°F (18.7°C) | 25600 |
| FX6-415350-149 | 415 | 3 | 14.9 | 22 | DS | 32.5°F (18.1°C) | 50850 |
| FX6-415350-224 | 415 | 3 | 22.4 | 32.4 | DS | 23.5°F (13.1°C) | 76450 |
| FX6-440350-042 | 440 | 3 | 4.2 | 6.7 | DS | 19.0°F (10.5°C) | 14350 |
| FX6-440350-084 | 440 | 3 | 8.4 | 12.2 | DS | 37.8°F (21.1°C) | 28700 |
| FX6-440350-168 | 440 | 3 | 16.8 | 23.3 | DS | 36.5°F (20.3°C) | 57350 |
| FX6-440350-209 | 440 | 3 | 20.9 | 28.7 | DS | 22.1°F (12.2°C) | 71350 |
| ADD SUFFIX | DESCRIPTION |
|---|---|
| -T | Built-in thermostat. |
| -D | Built-in disconnect switch. |
| -P | Built-in pilot light. |
| -L | Large junction box. |
| -C | Heresite coating |
| -A | Stainless-steel cabinet. |
| -U | Continuous fan. |
| NOMINAL WATTAGE (kW) | MAX. ALTITUDE (FT) | AIR DELIVERY @70°F (CFM) | HORIZONTAL THROW (FT) | MAX. MOUNTING HEIGHT (FT) | MOTOR POWER (W) | MOTOR SPEED (RPM) | FAN DIAMETER (in) | NET WEIGHT (lbs) WITH DS5 | NET WEIGHT (lbs) WITHOUT DS5 | SHIPPING WEIGHT (lbs) WITH DS5 | SHIPPING WEIGHT (lbs) WITHOUT DS5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 12000 | 850 | 30 | 10 | 373 | 1725 | 12 | 152 | 140 | 206 | 194 |
| 5 | 8000 | 850 | 30 | 10 | 373 | 1725 | 12 | 152 | 140 | 206 | 194 |
| 7.5 | 10000 | 850 | 30 | 10 | 373 | 1725 | 12 | 152 | 140 | 206 | 194 |
| 10 | 7000 | 850 | 30 | 10 | 373 | 1725 | 12 | 152 | 140 | 206 | 194 |
| 15 | 10000 | 1750 | 40 | 10 | 373 | 1725 | 16 | 180 | 168 | 230 | 218 |
| 20 | 7000 | 1750 | 40 | 10 | 373 | 1725 | 16 | 180 | 168 | 230 | 218 |
| 25 | 10000 | 3600 | 70 | 20 | 373 | 1725 | 20 | 213 | 201 | 264 | 252 |
| 30 | 7000 | 3600 | 70 | 20 | 373 | 1725 | 20 | 213 | 201 | 264 | 252 |
| 35 | 6000 | 3600 | 70 | 20 | 373 | 1725 | 20 | 213 | 201 | 264 | 252 |
| NOMINAL WATTAGE (kW) | MAX. ALTITUDE (FT) | AIR DELIVERY @70°F (CFM) | HORIZONTAL THROW (FT) | MAX. MOUNTING HEIGHT (FT) | MOTOR POWER (W) | MOTOR SPEED (RPM) | FAN DIAMETER (in) | NET WEIGHT (lbs) WITH DS5 | NET WEIGHT (lbs) WITHOUT DS5 | SHIPPING WEIGHT (lbs) WITH DS5 | SHIPPING WEIGHT (lbs) WITHOUT DS5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2.5 | 12000 | 700 | 25 | 10 | 187 | 1437 | 12 | 152 | 140 | 206 | 194 |
| 3.7 & 4.2 | 8000 | 700 | 25 | 10 | 187 | 1437 | 12 | 152 | 140 | 206 | 194 |
| 6.3 & 7.5 | 10000 | 700 | 25 | 10 | 187 | 1437 | 12 | 152 | 140 | 206 | 194 |
| 8.4 | 7000 | 700 | 25 | 10 | 187 | 1437 | 12 | 152 | 140 | 206 | 194 |
| 12.5 & 12.6 | 10000 | 1450 | 35 | 10 | 187 | 1437 | 16 | 180 | 168 | 230 | 218 |
| 14.9 & 16.7 | 7000 | 1450 | 35 | 10 | 187 | 1437 | 16 | 180 | 168 | 230 | 218 |
| 20.9 | 10000 | 3000 | 60 | 20 | 187 | 1437 | 16 | 213 | 201 | 264 | 252 |
| 22.4 | 7000 | 3000 | 60 | 20 | 187 | 1437 | 16 | 213 | 201 | 264 | 252 |
Furnish and install King Electric FX6 explosion proof heater. Unit shall be cULus certified for hazardous locations and shall include explosion proof motor, heavy duty heater core, epoxy coated 12 gauge steel cabinet, adjustable louvers, aluminum fan, NEMA Type 7 and 9 enclosure, two levels of over temperature protection, and wall or ceiling mounting capability. Heater shall be suitable for specified hazardous location classifications and low ambient operating temperatures down to -58°F (-50°C).


CX1 heaters are UL certified for use in hazardous locations. Designed to satisfy the demanding requirements of the oil and gas well drilling industry.
View Products

FX6 heaters are UL certified for use in hazardous locations. Designed for use in the harshest environments and indoor industrial locations.
View Products

FX6 heaters are UL certified for use in hazardous locations. Designed for use in the harshest environments and indoor industrial locations.
View Products

PCKF portables are outdoor-rated, FAA-approved for tarmac use, and the best source of clean, dry electric heat for “dry-out” applications where electric is preferred over propane or kerosene.
View Products